High precision sc cavity diagnostics with HOM measurements.
J. Frisch, L. Hendrickson, D. McCormick, Justin May, S. Molloy, M. Ross, T. Smith, N. Eddy, S. Nagaitsev, N. Baboi, O. Hensler, L. Petrosyan, O. Napoly, R. Paparella, C. Simon
Experiments at the FLASH linac at DESY have demonstrated that the Higher Order Modes induced in Superconducting Cavities can be used to provide a variety of beam and cavity diagnostics. The centers of the cavities can be determined from the beam orbit which produces minimum power in the dipole HOM modes. The phase and amplitude of the dipole modes can be used as a high resolution beam position monitor, and the phase of the monopole modes to measure the beam phase relative to the accelerator RF.  Beam orbit feedback which minimizes the dipole HOM power in a set of structures has been demonstrated. 
For most SC accelerators, the existing HOM couplers provide the necessary signals, and the downmix and digitizing electronics are straightforward, similar to those for a conventional BPM.

 